Displaying 21 - 40 of 2315
WS_TDG_35_11_2016.pdf [PDF] - 3.55 MB
… side are connected, they can be analysed as a continuous beam. As shown in Figure 5.1, diaphragms with simple plan … to use: to calculate both to obtain an envelope; to use a beam on elastic support approach (beam and elastic support … Connection Between Single Timber Floor Elements9 To connect two single floor panels together, the following …
WS_TDG_38_17_10_16.pdf [PDF] - 12.8 MB
… 33 4.6 External Walls / Building Facades … plates and central noggings of the same dimension and of party wall design (two frames). No of studs (6/0.45) + 1 say … between studs on the non-fire side of the cavity. The party wall arrangement was selected to represent a worse case …
WS_TDG_39_10_2016.pdf [PDF] - 7.72 MB
… 28 4.4.1 Precast Cores/Walls … loadbearing precast apartment building caused the flank walls in one corner to be blown out. This caused the collapse … The primary fault was that the joints between the precast walls and floors were inadequate for any blast load but, more … to do once openings are introduced but useful for party walls) • floor cassettes designed to double span in …
… 5 1.2 How to Use this Guide … 6 2 Building Codes and Standards 7 2.1 National Construction … and installed tie-downs and bracing detailed in AS 1684. Under normal circumstances, the house structure carries … 1 and Class 10a buildings within the size limits in AS 1684 and AS 4055 (see Section 2.3.1). The Guide does not …
WS_TDG_07_1_17.pdf [PDF] - 3.11 MB
… Plywood Box Beam Construction for Detached Housing Page 3 Table of Contents Introduction 4 Section 1: Engineers … Beam Design Data 6 Section 3: Load Terminology Used in the Span Tables 8 Section 4: Beam Components and Fabrication 12 Section 5: Installation 13 Section 6: Span Tables 16 #07 • Plywood Box Beam Construction for …
WS_TDG_05_1_17.pdf [PDF] - 7.14 MB
… M.N., Leicester, R.H. and Wang, C-H. “Manual No. 7: Marine borer attack.” 6. Leicester, R.H., Wang, C-H. and Nguyen, … lyctus susceptibility, termite resistance and marine borer resistance. Page 10#05 • Timber Service Life Design … protected from termites Insects other than termites (e.g. lyctid borer) Framing, flooring, furni- ture, interior …
… 17 Technical Design Guide issued by Forest and Wood Products Australia … to professionals and companies involved in building design and construction. WoodSolutions is resourced by Forest … of Forest and Wood Products Australia Limited. Technical Design Guides A growing suite of information, technical and …