This section contains a worked example which evaluates the flexural, shear and bearing performance of a 140 × 45 MGP10 seasoned floor joist for an office under loads (given as unfactored line loads distributed along the length of the member):

  • Worked Example - Performance Check Bending Member 
AttachmentSize
PDF icon Flexure_Capacity.pdf1.63 MB